Regenerative catalytic oxidizer – REF. 76-24

PLANT TYPE:Regenerative catalytic oxidizer
MAX AIR FLOW:15.000 Nm³/h
INSTALLED ELECTRIC POWER:30 kW
GAS BURNER CAPACITY:150 kW
ADDITIONAL FUEL:Natural gas
AVAILABILITY: August 2024
CONSTRUCTION YEAR:2013
DIMENSIONS (M): 6 X 2,5 X 2,5 h
STACK HEIGHT (M): 8

Regenerative thermal oxidizer – REF. 75-24

PLANT TYPE:Regenerative thermal oxidizer
MAX AIR FLOW:45.000 Nm³/h
INSTALLED ELECTRIC POWER:120 kW
GAS BURNER CAPACITY:1.100 kW
ADDITIONAL FUEL:Diesel oil
AVAILABILITY:July 2024
CONSTRUCTION YEAR:2010
DIMENSIONS (M):14 X 9 X 7 h
STACK HEIGHT (M):12
HOT OIL HEAT RECOVERY UNIT:1.100 kW
HOT WATER HEAT RECOVERY UNIT:700 kW

Regenerative thermal oxidizer – REF. 74-23

PLANT TYPE:Regenerative thermal oxidizer
MAX AIR FLOW:16.500 Nm³/h
INSTALLED ELECTRIC POWER:60 kW
GAS BURNER CAPACITY:400 kW
ADDITIONAL FUEL:Natural gas
AVAILABILITY:June 2024
CONSTRUCTION YEAR:2009
DIMENSIONS (M):12 X 3,5 X 5 h
STACK HEIGHT (M):7

Regenerative thermal oxidizer – REF. 73-23

PLANT TYPE:Regenerative thermal oxidizer
MAX AIR FLOW:12.000 Nm³/h
INSTALLED ELECTRIC POWER:50 kW
GAS BURNER CAPACITY:350 kW
ADDITIONAL FUEL:Natural gas
AVAILABILITY:July 2025
CONSTRUCTION YEAR:2007
DIMENSIONS (M):10 X 4,5 X 6 h
STACK HEIGHT (M):10

Regenerative thermal oxidizer – REF. 72-23

PLANT TYPE:Regenerative thermal oxidizer
MAX AIR FLOW:24.000 Nm³/h
INSTALLED ELECTRIC POWER:80 kW
GAS BURNER CAPACITY:600 kW
ADDITIONAL FUEL:Natural gas
AVAILABILITY:AVAILABLE
CONSTRUCTION YEAR:2007
DIMENSIONS (M):7 X 3 X 5,2 h
STACK HEIGHT (M):10

Activated Carbon Filtration Unit – REF. 71-23

PLANT TYPE:Activated Carbon Filtration Unit
FLOW RATE:5.000 Nm³/h
ELECTRICAL POWER:45 kW
AVAILABILITY: available
CONSTRUCTION YEAR:2022
DIMENSIONS (M): 10 X 5,5 X 4
STACK HEIGHT (M):8

Regenerative thermal oxidizer – REF. 69-23

PLANT TYPE:Regenerative thermal oxidizer
MAX AIR FLOW:12.000 Nm³/h
INSTALLED ELECTRIC POWER:35 kW
GAS BURNER CAPACITY:400 kW
ADDITIONAL FUEL:Natural gas
AVAILABILITY:AVAILABLE
CONSTRUCTION YEAR:2017
DIMENSIONS (M):11 x 3 x 3,8 h
STACK HEIGHT (M):10

Regenerative thermal oxidizer – Ref. 67/22

PLANT TYPE:Regenerative thermal oxidizer
MAX AIR FLOW:4.000 Nm³/h
INSTALLED ELECTRIC POWER:22 kW
GAS BURNER CAPACITY:130 kW
ADDITIONAL FUEL:Natural gas
AVAILABILITY:January 2023
CONSTRUCTION YEAR:2008
DIMENSIONS (M):8,4 X 3,5 X h 6,0
STACK HEIGHT (M):10

Regenerative thermal oxidizer – Ref. 65/21

PLANT TYPE:Regenerative thermal oxidizer
MAX AIR FLOW:7.000 Nm³/h
INSTALLED ELECTRIC POWER:36 kW
GAS BURNER CAPACITY:236 kW
ADDITIONAL FUEL:Natural gas
AVAILABILITY:November 2021
CONSTRUCTION YEAR:2007
DIMENSIONS (M):2,2 X 7,6 X h 3,65
STACK HEIGHT (M):10,2

Regenerative thermal oxidizer – Ref. 59/20

PLANT TYPE:Regenerative thermal oxidizer
MAX AIR FLOW:2.500 Nm³/h
INSTALLED ELECTRIC POWER:10 kW
GAS BURNER CAPACITY:70 kW
ADDITIONAL FUEL:Natural gas
AVAILABILITY:December 2023
CONSTRUCTION YEAR:2018
DIMENSIONS (M):9 x 3 x 4
STACK HEIGHT (M):10

Those who in any way utilize the product(s) are solely responsible for determining (a) the suitability of the product for the intended use, (b) the appropriate manner of processing and maintaining the product to ensure safety and quality and (c) chemical, physical and health effects related to those activities, (d) to inform themselves in order to be able to decide if specific data are necessary for their intended use in respect to norms and regulations in application at the location of their intended use. Performance data given in this document is provided as a guide for the user to determining suitability. Dimensions and weights are nominal and are not be used for manufacturing, even when tolerances are shown. Please read and understand this document before purchasing the product. Please contact your Brofind Spa representative if you have any questions or comments. Unless specifically mentioned in the document, all data, whenever a notion of safety factor or safety parameter to be taken into account may be implied or requested, is expressed without. Customers, installers and third parties are solely responsible for damages or failures in performance resulting from misuse, abuse, neglect or improper handling, transporting or storage.